Klinisk Biokemi i Norden Nr 4, vol. 29, 2017 - page 26

26 | 
Klinisk Biokemi i Norden · 4 2017
in the range 0-70 grams and %CDT value:
validation of a cut-off value. Alcohol Alcohol
2005;40:531-4.
8. Oberrauch W, Bergman AC, Helander A.
HPLC andmass spectrometric characterization
of a candidate reference material for the alcohol
biomarker carbohydrate-deficient transferrin
(CDT). Clin Chim Acta 2008;395:142-5.
9. Helander A. Absolute or relative measurement
of carbohydrate-deficient transferrin in serum?
Experiences with three immunological assays.
Clin Chem 1999;45:131-5.
10. Helander A, Eriksson G, Stibler H, Jeppsson
J-O. Interference of transferrin isoform types
with carbohydrate-deficient transferrin quan-
tification in the identification of alcohol abuse.
Clin Chem 2001;47:1225-33.
11. Arndt T, van der Meijden BB, Wielders JP. Aty-
pical serum transferrin isoform distribution
in liver cirrhosis studied by HPLC, capillary
electrophoresis and transferrin genotyping.
Clin Chim Acta 2008;394:42-6.
12. Helander A, Bergström J, Freeze HH. Testing
for congenital disorders of glycosylation by
HPLC measurement of serum transferrin gly-
coforms. Clin Chem 2004;50:954-8.
13. Jeppsson J-O. Isolation and partial characte-
rization of three human transferrin variants.
Biochim Biophys Acta 1967;140:468-76.
14. Helander A, Wielders JP, Te Stroet R, Berg-
str
ö
m JP. Comparison of HPLC and capillary
electrophoresis for confirmatory testing of the
alcohol misuse marker carbohydrate-deficient
transferrin. Clin Chem 2005;51:1528-31.
15. Jeppsson J-O, Arndt T, Schellenberg F, Wielders
JP, Anton RF, Whitfield JB, et al. Toward stan-
dardization of carbohydrate-deficient transfer-
rin (CDT) measurements: I. Analyte definition
and proposal of a candidate reference method.
Clin Chem Lab Med 2007;45:558-62.
16. Schellenberg F, Wielders J, Anton R, Bian-
chi V, Deenmamode J, Weykamp C, et al.
IFCC approved HPLC reference measure-
ment procedure for the alcohol consumption
biomarker carbohydrate-deficient transferrin
(CDT): Its validation and use. Clin Chim Acta
2017;465:91-100.
17. Helander A, Wielders JP, Jeppsson J-O, Wey-
kamp C, Siebelder C, Anton RF, et al. Toward
standardization of carbohydrate-deficient
transferrin (CDT) measurements: II. Perfor-
mance of a laboratory network running the
HPLC candidate reference measurement pro-
cedure and evaluation of a candidate reference
material. Clin Chem LabMed 2010;48:1585-92.
18. Weykamp C, Wielders JP, Helander A, Anton
RF, Bianchi V, Jeppsson J-O, et al. Toward
standardization of carbohydrate-deficient
transferrin (CDT) measurements: III. Perfor-
mance of native serum and serum spiked with
disialotransferrin proves that harmonization
of CDT assays is possible. Clin Chem Lab Med
2013;51:991-6.
19. Weykamp C, Wielders J, Helander A, Anton
RF, Bianchi V, Jeppsson J-O, et al. Harmoni-
zation of measurement results of the alcohol
biomarker carbohydrate-deficient transferrin
by use of the toolbox of technical procedures of
the International Consortium for Harmoniza-
tion of Clinical Laboratory Results. Clin Chem
2014;60:945-53.
20. Helander A, Carlsson AV, Borg S. Longitu-
dinal comparison of carbohydrate-deficient
transferrin and gamma-glutamyl transferase:
complementary markers of excessive alcohol
consumption. Alcohol Alcohol 1996;31:101-7.
21. Bergström JP, Helander A. Clinical characte-
ristics of carbohydrate-deficient transferrin
(%disialotransferrin) measured by HPLC: sen-
sitivity, specificity, gender effects, and relation-
ship with other alcohol biomarkers. Alcohol
Alcohol 2008;43:436-41.
22. Kenan N, Larsson A, Axelsson O, Helander A.
Changes in transferrin glycosylation during
pregnancy may lead to false-positive carbo-
hydrate-deficient transferrin (CDT) results in
testing for riskful alcohol consumption. Clin
Chim Acta 2011;412:129-33.
23. Helander A, Jaeken J, Matthijs G, Eggertsen
G. Asymptomatic phosphomannose isome-
rase deficiency (MPI-CDG) initially mistaken
for excessive alcohol consumption. Clin Chim
Acta 2014;431:15-8.